Skip to content
-

- Crowcon GM64 Addressable Gas Panel
- Support for 64 Addressable Gas Detectors – in single panel.
- Support for up-to 16 / 64 / 128 Fixed Gas Detectors.
- GM16 / GM64 / GM128 Available in Different Configurations.
- 4-20mA Analog & RS-485 MODBUS Standard Communication.
- Direct Web page live feed communication – For BMS Integration.
- Multiple Data & Zone Screens available – Real Time Readings.
- Available in Fiberglass Enclosures, 19″ rack mount or aluminium.
- Contact us for more information.
-

- Battery Room Gas Monitoring – Fixed Detection Systems.
- Detect hydrogen gas release & accumulation in battery rooms.
- For use in rooms with NiCad & Lead-acid (Pb) type batteries.
- Dual sensor monitoring for redundant hydrogen gas detection.
- Lithium batteries emit hydrogen, methane & carbon monoxide.
- Customized solution for battery backup & energy storage systems.
- Integration to building BMS, PLC, SCADA or Fire Alarm System.
- Ensure accurate detector placement, detection & battery risks.
- Critical maintenance, testing & calibration of H2 gas detectors.
- Suitable for battery rooms, electrical rooms & UPS Rooms.
- Early detection of off-gassing caused by thermal runaway.
- Ensure code compliance to NFPA, IEEE & EN Standards.
- Contact us for more information.
-

- Specialty Mixed Calibration Gas
- Included Regulator & PVC Hose
- Additional Accessories / Calibration Equipment
- Included Analytical Certificate with Calibration Cylinder.
- Regulator 0.5L/min or 1L/min – Brass for Flammable Gas & SS for H2S.
- Different Gas Mix Available – Flammable, Oxygen & Toxic.
- Contact us for more information.
-

- Crowcon Gasmaster 4 Channel Gas Control Panel.
- Capable up-to 4 Oxygen, Toxic or Flammable Gas Detectors.
- Each detector assigned 2 levels of independent alarm.
- Push buttons and LED Display enable easy operation.
- Functional Certification & Capable – SIL 2 Certified.
- RS-485 MODBUS communication for DCS/PLC/SCADA.
- Battery Backup – For operation in case of power failure.
- Fire Alarm Control Panel Integration & Networking.
- Event Logger – To Measure, Fire, Gas & Fault Alarms.
- Contact us for more information.
-

- Crowcon Gasmonitor Plus – Rack Mount Gas Detection Panel.
- Gasmonitor+ is designed for custom configuration systems.
- Modular System Cards for Fire & Gas Detection System.
- Systems can be integrated into custom rack mount panel 3U.
- Integrate 4-20mA Toxic, Flammable & Oxygen Gas Detectors.
- Relay output with configuration as required for A/V & Outputs.
- Customized voting parameters for flexible output control signals.
- Integrate up-to 20 conventional smoke & heat detectors directly.
- Integrate up-to 16 gas detectors per rack / interchangeable for fire.
- 4-20mA Analogue Outputs or 24Vdc Audio Visual Alarm Drive unit.
- Power: 240Vac 60Hz with battery or Optional 24Vdc powered unit.
- Suitable for use in shelter, refuge centers or rack mount applications.
- Systems are highly scalable, modular and flexible based on demand.
- SIL 2 Approved for highly demanding safety & failure free operation.
- Contact us for more information.
-

- Crowcon Gas Control Panel
- Custom PLC based Engineered Rack Systems
- Can support 13 or more Detectors (Flexible) – Conventional System
- Push Buttons & LED Display reading for each detector
- MODBUS Compatible
- SIL-1 Certified
- Battery Backup / UPS
- Available in Panel Mount / Wall Mount / Custom Rack Solutions
-

- Crowcon Air Aspirated Sample Systems/ Gas Sampling System.
- Only Sampling System usable in Hazardous Area based on installation.
- Uses eductor for sampling (using Venturi Effect) – The eductor is driven by compressed air to create a negative pressure to draw the sample.
- Electrical Components are the sensor and Intrinsically Safe flow device.
- Principle: The air aspirated system uses a compressed air driven vacuum generator to draw a gas sample from a single point. Explosion proof gas detectors are fitted to monitor for flammable gases & toxic gases.
- Flow rate is limited to 1m/sec – Can be adjusted as per request & approved design with factory approvals.
- Certified for use in Zone 1 or Zone 2 hazardous areas, IP-65 Rated.
- Customized Engineered Solutions & Support from Factory for Design.
- Contact us for more information.
-

- Crowcon Gasflag – Single Channel Monitor.
- Capable of monitoring one 4-20mA flammable, toxic or oxygen gas detector.
- Can be used in LPG Monitoring or locations with 1 Gas Detector.
- 3 Relay Outputs – For Alarm 1, Alarm 2 & Fault Relay Activation.
- Rising & Falling Alarm Setpoints for Oxygen Detectors.
- Two Rising Alarms for Flammable & Toxic Detectors.
- Can be used for any 4-20mA Analog Gas Detector.
- IP-20 Protection – Basic Protection from Dust.
- Contact us for more information.
-

- Crowcon Gasmaster – 1-4 Channel Control Panel.
- Capable up-to 4 Oxygen or Toxic Gas Detectors.
- Each detector assigned 2 levels of independent alarm.
- Push buttons and LED Display enable easy operation.
- Functional Certification & Capable – SIL 2 Certified.
- Battery Backup – For operation in case of power failure.
- Fire Alarm Control Panel Integration & Networking.
- RS-485 MODBUS RTU – Network & BMS Integration.
- Event Logger – To Measure, Fire, Gas & Fault Alarms.
- Contact us for more information.
-

- Crowngas offers integrated fire & gas detection systems solutions.
- Turnkey engineered solutions for design, supply & commissioning.
- Custom factory assembled fire & gas controllers & IFG Systems.
- Modular controllers enable conventional fire zones & analog inputs.
- IFG Systems designed & engineered for large builders to small cabins.
- IFG System can optionally be mounted in Ex d’ ATEX certified enclosure.
- Fire zone capable of taking Apollo I.S Smoke, Heat & MCP Devices.
- Gas input capable for analog input of toxic, flammable & flame detectors.
- Small IFG Systems suitable for use in custom shelters & porta-cabins.
- Optional remote HMI for testing, action, reset & maintenance as required.
- Contact us for more information.
-

- Multiscan 8+ Gas Panel.
- Monitor up-to 16 Gas Detectors – Conventional & Addressable.
- 8 Conventional Gas Detector + 8 Addressable Gas Detector (RS485).
- Support for 4-20mA Analog Signals & RS-485 MODBUS.
- Event logging – For Alarm Monitoring & Signal Activation.
- Battery back-up – Ensure Gas Detection is on in case of power failure.
- Contact us for more information.
-

- Crowcon Multiscan++S2 Gas Control Panel
- SIL 2 Certified for use in demanding areas.
- Monitor & manage up-to 256 Gas Detectors.
- Enclosure: ABS or Aluminium Rack
- Support for 16 / 32 / 64 / 128 / 256 Inputs.
- Support for 32 / 64 / 128 / 256 / 516 Outputs.
- Internal Self-Test to detect failures.
- Available in Panel & Rack Mount for use in custom racks.
- Galvanic isolated loops for hazardous area installation.
- Digital Communication between detectors.
- Explosion Proof Certified for use in Hazardous Areas.
- Built in event log & Status LED.
- Contact us for more information.
-

- Refrigerant Leak Detection System – Fixed Installation.
- Detection of refrigerant gases emanating from HVAC.
- Refrigerant Gas Detectors are to be installed near leaks.
- Suitable for use in chiller rooms & mechanical rooms.
- Refrigerant Detectors shall activate the leak extract fans.
- Activation to solenoid valves or alarm & visual signals.
- Signaling to chiller plant management & ventilation.
- Detect wide range of freons, HFCs, CFCs & NH3 gas.
- Optional integration to BMS or Fire Alarm System.
- Detection of a wide variety of refrigerant gases.
- Contact us for more information.
-

- Crowcon Environmental Sampling Unit / Sampling Gas Detector.
- Low-cost Air Sampling Unit for HVAC & other critical Equipment.
- Detection of toxic / flammable gases in hot, humid or dusty environments.
- Single Point / Multi Point / Sequential / Aspirated Sample System.
- Low & High Alarms signals to program Relays for Shutdown / AV Units.
- Single Point – Gas Detector using Pellistor / IR Sensor for High Temps.
- Multi Point – Made of Multiple Point for Environmental Gas Monitoring.
- Engineered / Customized Solutions available certified for Hazardous Areas (with 1, 2 or 3 sensors) and Non-Hazardous Areas. Can be programmed for executive action based on detection from multiple detectors.
- Contact us for more information.
-

- Crowcon Vortex – Gas Control Panel.
- Capable up-to 12 Oxygen, Toxic or Flammable Gas Detectors with (including 3 for Fire).
- Each detector assigned 1 Fault Level & 3 Alarm Levels to trigger up-to 32 output relays.
- Push buttons and LED Display enable easy operation – Real Time Gas Readings of Detectors.
- Can be integrated with Manual Call Points & Other Safety Systems – Support for Fire Loops.
- SIL 1 Certified – for use with Safety Instrumented Systems – Functional Safety & Integrity.
- Battery Backup & MODBUS, RS-485 Integration – For BMS & Scada Integration – Networking.
- Available in Wall Mount, 19″ Rack mount, Panel Mount – For all site requirements & design.
- Custom design based for site approved design – for client’s custom PLC Board & Equipment.
- Contact us for more information.
-

- Crowcon Vortex FP – Flameproof Gas Panel
- Used in Hazardous areas – both onshore & offshore
- Flameproof Gas Detector Control Panel
- Made with LM25 Aluminium with polyester powder coating.
- Support for up-to 12 Gas Detector (including 3 loops for fire – up-to 20 devices per loop)
- Capable of up-to 32 relay outputs.
- RS-485 MODBUS or PROFIBUS
- Store up-to 300 alarm, power, fault, system events.
- ATEX Certified – for use in Explosion Proof Areas
- Available in FP or FP Compact
- Contact us for configuration & consult.
-

- Crowcon Vortex FP Compact – Flameproof Gas Panel
- Used in Hazardous areas – both onshore & offshore.
- Flameproof Gas Detector Control Panel.
- Made with LM25 Aluminium with polyester powder coating.
- Support for up-to 12 Gas Detector (including 3 loops for fire – up-to 20 devices per loop)
- Capable of up-to 16 relay outputs – For Signaling, Fire Panel & PLC Integration.
- RS-485 MODBUS or PROFIBUS – For BMS & SCADA Integration – Networking.
- Event Logger – Store up-to 300 alarm, power, fault, system events.
- Explosion Proof – ATEX Certified for use in hazardous areas.
- Available in FP or FP Compact – Different Sizes & Designs.
- Contact us for configuration & consult.
-

- Water Detection System – For Data Center & Pump Rooms.
- Customized leak sensing cable for large area coverage.
- Probe type sensors for leak detection in sump pits & outdoors.
- Relay Outputs Available – For Executive Action & Signaling.
- From small systems (3m cable) to large (3000m) systems.
- Outputs: BMS, BACnet, PLC, SCADA & Integration Features.
- Wireless Water Leak Detection System for existing facility.
- Detects Water Ingress & Initiates Signaling – Linear Wire.
- To be used in Areas with Sensitive Electrical Equipment.
- Server Rooms, Battery Rooms, Switchgear & Storage Areas.
- Contact us for more information.
-

- Wireless Control Systems – For Existing Facilities.
- Facility Monitoring Systems are ideal for cable free installation.
- Wireless Control systems for commercial & industrial use cases.
- Systems involve a transmitter with each unit and a receiver.
- Receiver shall have an antenna to interface every transmitter.
- Wireless transmitters have a battery life of over 10 years.
- Wireless temperature sensors & monitoring systems.
- Wireless temperature & humidity sensors & monitoring.
- Wireless Water Leak Detection System – Linear Cable Type.
- Wireless Water Leak Detection System – Probe / Point Type.
- Wireless Transmitter – Receives wired NO or NC digital input.
- Wireless Transmitter – Receives Analog 4-20mA Analog input.
- Wireless Gas Detection System – For Indoors & Outdoors.
- Wireless Systems can be of Wi-Fi type or Radio Frequency Type.
- Receiver Systems can integrate into BMS via Modbus or BACnet.
- Custom mapping features display status of wireless transmitters.
- Wireless Systems can be used to fine tune your facility management.
- Contact us for more information.