Skip to content
ATEX Certified Fire Alarm Devices – Fire & Gas Systems.
Intrinsically Safe Smoke & Heat Detectors – Conventional.
Intrinsically Safe Probe Type Heat Detectors – Conventional.
Intrinsically Safe Sounders, Flashers & Strobe Beacons.
Intrinsically Safe Manual Call Points – QCD Approved.
Intrinsically Safe Linear Heat Detection – QCD Approved.
Explosion Proof Manual Call Points & Push Button Devices.
Explosion Proof Dual Action MCP for fire suppression systems.
Explosion Proof Sounders, Flashers & Audio Visual Devices.
Explosion Proof Beam Detectors – QCD Product Approved.
Explosion Proof Emergency Lights – QCD Product Approved.
Explosion Proof Exit Signs & Lights – QCD Product Approved.
Explosion Proof Fixed Gas Detectors & Detection Systems.
Double Action Pull Handle MCP – Manual Call Point Range.
Double Action Type Prevents False or Accidental Activation.
Type 1: Lift Flap & Pull Handle for Alarm Activation & Signal.
Type 2: Push Bar & Pull Handle for Alarm Activation & Signal.
Switch Type: Single Changeover or Double Changeover (DPDT).
Material: GRP, Marine Grade Alloy & Stainless-Steel Fixings.
Temperature: -55°C to +70°C for use in offshore & refineries.
Eaton MEDC Variant: PH1 Range Pull Handle Manual Call Point.
E2S Variant: D1xCP1-PS Explosion Proof Manual Pull Station.
SIL2 Approved Variants available for highly redundant systems.
Contact us for information.
Explosion Proof Alarm Bell – Notification Devices.
Suitable for use in Zone 1 & 2 Hazardous Areas.
Enclosure: Cast Iron, GRP or Aluminium Cover.
Ingress Protection: IP65, IP66 & IP67 Certified.
Sound Output: 109 db(A) & 106 dB(A) Options.
Eaton MEDC: DB6 Alarm Bell for up-to 109 dB(A).
Operating Voltage: 24Vdc, 240Vac & more.
Corrosion proof & optional swivel bracket.
Contact us for more information.
Explosion Proof Beacons – Hazardous Area Rated – Safety & Telecom.
Beacons available in Xenon Lamp or LED Type for High Light Output.
Enclosure: GRP, Marine Grade Alloy or Stainless Steel 316L (SS 316L).
Beacons are available in strobe, rotating, flashing & steady configuration.
High Temperature Units as per indoor or outdoor installation & mounting.
Marine listed for vessel and offshore applications in saline environments.
SIL 1 and SIL 2 Safety Level Rated Beacons – Ensure Safe Operation.
Zone 1 & Zone 2 Hazardous Area rated for fire alarm & visual signaling.
Eaton MEDC: MEDC XB15, MEDC XB9, MEDC XB8, MEDC XB4, MEDC XB13, MEDC XB12, MEDC TH12, MEDC XB87LED, MEDC SM87HXB, MEDC LD15 – Eaton Crouse Hinds Rated Explosion Proof Xenon and LED Beacons.
E2S: E2S D1xB2, E2S GNExB2, E2S STExB2, E2S BExBG, E2S D1xB2, E2S GNExB2, E2S STExB2, E2S GNExB1, E2S BExBG, E2S D2xB1, E2S E2xB, E2S IS-L101L LED Beacon, E2S STExB2 Rotating Beacon – E2S Visual Signals.
Federal Signal: G-STR Strobe Beacon, 154XSTHI, 224XTSHI, FB245THI.
Units available with QCD (Qatar Civil Defense) Approvals for Fire Alarm.
Contact us for more information.
Explosion Proof Break Glass MCP – Manual Call Point.
Conventional Type Break Glass MCP for Hazardous Areas.
Available in Replaceable Break Glass or Plastic Element.
MCP used to raise alarm during fire, gas release or ESD.
Eaton MEDC Crouse Hinds Models: BG, BG2, BG3, SM87BG.
E2S Models: GNExCP7, STExCP8, GNExCP6, BExCP3, IS-CP4.
Enclosure: GRP, Marine Grade Aluminium Alloy or SS 316.
IP Rating: IP66 / IP67 Weatherproof and corrosion proof.
Switch Type: Single Changeover or Double Changeover.
Color: Red (standard), black, blue or as per choice/demand.
Optional: LED Indicator, Series Resistance, EOL & Diode.
SIL 2 Certification for use with Fail-Safe Systems & Alarm.
Contact us for more information.
Explosion Proof Loudspeaker – E2S, MEDC & DNH AS.
Loudspeaker Power Ranges: 8W, 15W, 25W & more.
Temperature Ranges: -60°C to +85°C for wide range.
Protection: Weatherproof Type with IP65, IP66 & IP67.
Material: Marine grade alloy or stainless-steel option.
Wide range of SPL (Sound Pressure Level) availability.
Color: Standard Red or Black, Optional Color Choices.
E2S Models: BExL, GNExL, STExL1, D1xL, D2xL& E2xL.
Eaton MEDC Models: DB4B, DB4BM, DB10 & DB20.
DNH AS Models: DSP-15, DSP-25, HS-15 & MF Models.
Federal Signal Models: ASHX, ASUX, 300X, ASHH & ASUH.
Redundancy: SIL2 Approved Models for Fire Alarm Systems.
Suitable for digital voice message & live public addressing.
Contact us for more info on supply & configuration.
Explosion Proof Pull Stations – Pull Handle Type.
Conventional Type Pull Station Call Point for Hazardous Areas.
Ideal for use in extreme weather and corrosive environments.
Pull Station available in two types – lift & pull or push & pull.
IP Rating: NEMA Type 4X & IP66/67 Weatherproof Protection.
Color: Standard Red, Optional Blue, Yellow or Custom Colors.
Enclosure: Cast Aluminium or Glass Reinforced Polyester (GRP).
SIL 2 Compliant to maintain functional integrity of fire alarm system.
Entries: 3/4″ NPT, 1/2″ NPT or Standard M20 Entries with Adaptors.
Custom Labels, tags & equipment tags in stainless steel plates.
Optional Accessories: Pole Mount Bracket Kit or Sunshade Kits.
QCD Approved – Qatar Civil Defense approved models available.
Contact us for more information.
Explosion Proof Push Button – Manual Call Point Range.
Suitable for use in Fire Alarm Systems & Suppression Devices.
Type 1: Tool Reset Manual Station Call Point for Confirmed Fire.
Type 2: Turn & Push Type for Double Action Redundant Signaling.
Type 3: Momentary Latching / Self Reset Type Push Buttons.
Switch Type: Single Changeover or Double Changeover (DPDT).
Material: GRP, Marine Grade Alloy & Stainless-Steel Fixings.
Temperature: -55°C to +70°C for use in offshore & refineries.
Eaton MEDC Variant: MEDC PB & MEDC SM87PB MCP Range.
E2S Variant: GNExCP7, STExCP8, GNExCP6, BExCP3 & IS-CP4.
SIL2 Approved Variants available for highly redundant systems.
Contact us for information.
Explosion Proof Sounder Beacon Units – Combination AV.
Integrated Audio-Visual Units for Hazardous Areas Signaling.
ATEX Certified for use in Harsh Explosive Atmospheres.
Combination units can be used for telephone signaling.
Beacons are of xenon strobe type with 21 Joule output.
Integrated sounders have a maximum sound of 125dbA.
Enclosure: GRP, LM6 Aluminium, 316 Stainless Steel type.
Intrinsically safe units are available for use with IS Barrier.
Units are corrosion proof with an IP 66 / 67 protection.
Custom fixture lights are available for Fire, Gas & Sounder.
Signaling lights with custom colors and SS nameplates.
Option: Factory Certified Units or Custom Configured.
Available MEDC: MEDC CU1, CU1S, CU1SP, CU1H, CU1HP.
Available E2S: BExCS, D1xC, STExC, IS-mC1, D2xC2, D2xC1, E2xC1.
QCD Certified units are available for use with fire alarm.
Contact us for more information.
Explosion Proof Sounders – E2S, MEDC & DNH AS.
Sounder Output: High Output Alarm Horn >120dB(A).
Temperature Ranges: -55°C to +85°C for wide range.
Protection: Weatherproof Type with IP65, IP66 & IP67.
Material: Marine grade alloy or stainless-steel option.
Color: Standard Red or Black, Optional Color Choices.
Type: Flare Horn / Radial Horn / Alarm Horn Sounder.
E2S Models: BExS, GNExS, STExS, D1xS, D2xS, E2xS.
Eaton MEDC Models: DB3B, DB3BM, DB5 & DB7.
Redundancy: SIL2 Approved Models for Fire Alarm.
Optional: Telephone Relay Initiate for telephones.
Custom Industry Standard Tones (28 Pre-Set Tones).
Contact us for more info on supply & configuration.
Explosion Proof Status Lamps – Signaling Devices.
Devices are suitable for use in Zone 1 & 2 Areas.
Light Options: LED, Xenon, Filament & Fluorescent.
Flash Options: Steady Light, Flashing with flash rates.
Enclosure: GRP, Marine Grade Alloy & Stainless Steel.
Lens Color Options: Red, Blue, Green, Amber, Yellow etc.
Eaton MEDC: SL15, SL5, SM87SL & XB12SL Variants.
Several Voltage Options & Cable Entry Sizes Available.
Suitable for marine, onshore & offshore environments.
Contact us for more information.
Crowngas supplies Approved Marine Fire Detectors.
Detectors are DNV, BV, ABS & Lloyd’s rated & approved.
Ranges include smoke, heat, dual sensor & flame detectors.
Apollo Orbis Conventional Marine Approved Fire Detectors.
Apollo Discovery Marine Approved Fire & Flame Detectors.
Tyco Marine – Minerva Addressable Fire & Flame Detectors.
Consilium Salwico Fire & Flame Detectors – DNV Approved.
Eaton Crouse Hinds MEDC – Marine Fire Pushbutton & MCP.
Deckhead mount kits to prevent water entry into detector.
Marine rated devices are also suitable for use in offshore.
QCD Approved for use with Fire Alarm System.
Contact us for more information.
MEDC XB8 Intrinsically Safe Beacons
Corrosion Resistant
Enclosure: GRP
High Intensity Flash
Clear Lens
Contact for more information.
MEDC Safe Area Xenon Beacons
Available in Weatherproof for Outdoor Areas – IP 65
High Intensity Flash
Enclosure: Corrosion Resistant GRP
Optional Lens Guard
Multi Lens & Enclosure Colours Available
Contact for more information & design.
MEDC High Output Xenon Beacons
SM87HXB, XB11, XB12, XB15, XB4
Designed for use in Hazardous Areas
Enclosure: GRP, LM35 Aluminium, SS 316
SIL 1, SIL 2 Beacons Available
Various Lens Color, Enclosure, Flashing Rates & Outputs
5J, 10J, 15 & 21 Joule Beacons
Custom tag & duty plates
Beacon / Sounder Combination unit Available
SS Screws
Contact for more information.